BVCLQ - 2104 AEROSOL, EXP-FINE-L KOTE URETHANE (SUPP DATA)

  • MSDS: BVCLQ
  • Manufacturer: TECH SPRAY
  • Product Name: 2104 AEROSOL, EXP-FINE-L KOTE URETHANE (SUPP DATA)
  • National Stock Number: 6850-00N048922
Product Identification

Product ID:2104 AEROSOL, EXP-FINE-L KOTE URETHANE (SUPP DATA)
MSDS Date:06/09/1993
FSC:6850
NIIN:00N048922
MSDS Number: BVCLQ

Responsible Party
TECH SPRAY
AMARILLO, TX 79105-0949
US

Emergency Phone: 800-858-4043

Info Phone: 806-372-8523

Cage: DO989

Contractor
TECH SPRAY INC
949 AMARILLO, TX 79105-0949 US

Telephone: 806-372-8523

Cage: 54700

Ingredients

LIFE-SUSTAINING USES IN HUMANS ACUTELY OR

RTECS: 9999999ZZ


STIMULANTS SHOULD NOT BE USED TO TREAT

RTECS: 9999999ZZ


SHUT OFF AIR CONDITIONING AND HEATING SYSTEMS

RTECS: 9999999ZZ


XYLENE (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: < 15%

OSHA PEL 100 PPM;150 STEL

ACGIH TLV: 100 PPM;150 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ACETIC ACID, PROPYL ESTER; (PROPYL ACETATE)

CAS: 109-60-4

RTECS: AJ3675000

Fraction By Weight: 15-20%

OSHA PEL 200 PPM;250 STEL

ACGIH TLV: 200 PPM;250 STEL


BENZENE, 2,4-DIISOCYANATO-1-METHYL;

CAS: 584-84-9

RTECS: CZ6300000

Fraction By Weight: 0.52%

OSHA PEL 0.02 PPM;0.02 STEL,C

ACGIH TLV: 0.005PPM;0.02 STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


OPTIC BRIGHTNER; (OPTICAL BRIGHTNER)

Fraction By Weight: <0.1%

OSHA PEL N/K

ACGIH TLV: N/K


URETHANE PREPOLYMER

Fraction By Weight: 8-10%

OSHA PEL N/K

ACGIH TLV: N/K


METHANE, CHLORODIFLUORO-; (CHLORODIFLUOROMETHANE)

CAS: 75-45-6

RTECS: PA6390000

Fraction By Weight: 15-20%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


ETHANE, 1,1-DICHLORO-1-FLUORO-; (DICHLOROFLUOROETHANE) (MFR

CAS: 1717-00-6

RTECS: KI0997000

OSHA PEL N/K

ACGIH TLV: N/K


TOLUENE-2,4-DIISOCYANATE CAN BE A STRONG

RTECS: 9999999ZZ


CHLOROFLUOROCARBON MATLS HAVE PRODUCED SENSIT OF THE

RTECS: 9999999ZZ


COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHAL: MAJOR POTENTIAL ROUTE OF
EXPOSURE. MINIMAL EFTS OBSERVED BELOW 1000 PPM. DIZZ, DROWSINESS, &
THROAT IRRIT POSSIBLE AT LEVELS ABOVE 1000 PPM. UNCONSCIOUSNESS &
DEATH AT LEVELS ABOVE 10000 PPM. B LOOD PRESSURE DEPRESSION,
CARDIAC SENSITIZATION, & VENTRICULAR ARRHYTHMIA CAN RSLT FROM
EXPOSURE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:TOLUENE DIISOCYANATE:IARC MONOGRAPHS,
SUPPLEMENT, VOL 7, PG 56, 1987: GRP 2B. ANTIC TO BE CARCIN, NTP 6TH
ANN RPT, 1991.
Effects of Overexposure:HLTH HAZ:TO NEAR-ANESTHETIC LEVELS. EYES: LIQ
CAN CAUSE SLIGHT, TEMPORARY IRRIT W/SLIGHT TEMPORARY CORNEAL
INJURY. VAPS CAN IRRIT EYES. SKIN: PRLNGD/RPTD SKIN CNTCT CAN CAUSE
IRRIT, DEFATTING OF TISSU ES, & DERMATITIS, ABSORPTION THROUGH
INTACT SKIN IS POSSIBLE IF CONTACT W/LIQUIDS IS PRLNGD. INGEST:
SINGLE (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. IF BRTHG HAS STOPPED, ADMINISTER
ARTF RESP. SEEK MED ATTN. EYES: FLUSH FOR @ LST 15 MIN W/CLEAR
WATER. IF IRRIT PERSISTS, SEEK MED ATTN. SKIN: REMOVE CONTAM CLTHG
& SHOES. WASH EXPOSED AREA W/SOAP AND WATER. WASH CONTAM CLTHG
BEFORE REUSE. INGEST: DO NOT INDUCE VOMIT! GIVE 2 GLASSES OF WATER
AND IMMED SEEK MED ATTN. NOTE: ADRENALINE & OTHER SIMILAR CARDIAC
(ING 12)

Fire Fighting

Flash Point Method:TCC
Flash Point:50.0F,10.0C
Lower Limits:1.0%
Upper Limits:7.0%
Extinguishing Media:WATER, FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD WEAR NIOSH/MSHA APPROVED
PRESSURE DEMAND SCBA AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:H*2O MAY CAUSE FROTHING IN OPEN CNTNRS.
CONC VAPS CAN BE IGNIT BY HIGH INTENSITY IGNIT SOURCE. THERMAL
DECOMP PRODS MAY INCL CHLORIDES/FLUORIDES/PHOSGENE.

Accidental Release

Spill Release Procedures:EVAC AREA, VENT, & AVOID BRTHG VAPS. DIKE AREA
TO CONTAIN SPILL. CLEAN UP AREA BY MOPPING OR W/SUITABLE ABSORBENT
MATL & PLACE IN CLSD CNTNRS FOR DISP. AVOID CONTAM OF GROUND & SURF
WATERS. DO NOT FLU SH TO SEWER. IF SPILL IS INDOORS, (ING 13)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP STORED IN COOL, DRY PLACE WITH
CONTAINER TIGHTLY CLOSED. KEEP THIS AND ALL CHEMICALS OUT OF REACH
OF CHILDREN. THIS FOR INDUST USE ONLY.
Other Precautions:BULK LIQ IS FLAMM, HOWEVER, W/PROPELLANT, FLAMM IS
SUPRESSED IN AEROSOL. NO SMOKING IN AREA OF USE. DO NOT USE IN GEN
VICINITY OF ARC WELDING/OPEN FLAME/HOT SURFS. HEAT &/OR UV RADIA
MAY CAUSE FORMATI ON OF CHLORIDES/FLUROIDES/PHOSGENE

Exposure Controls

Respiratory Protection:IF LEVELS EXCEED TLVS, INCREASED VENT OR
NIOSH/MSHA APPROVED ORGANIC VAPOR MASK REQUIRED.
Ventilation:DO NOT USE IN CLOSED SPACE. VENTILATION REQUIRED.
Protective Gloves:SOVLENT RESISTANT GLOVES; VITON, PVA.
Eye Protection:SPLASH PROOF SAFETY GOGGLES OR GLASSES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR TRADE NAME/PART NO: CONFORMAL COATING. EFTS OF OVEREXP: DOSE
TOXICITY IS LOW TO MODERATE. IF VOMITING OCCURS THE LIQUID CAN BE
ASPIRATED INTO THE LUNGS, WHICH CAN CAUSE CHEMICAL PNEUMONIA AND
SYST EMIC EFFECTS. HUMAN PSYCHOTROPIC, GASTROINTESTINAL, AND
CENTRAL NERVOUS SYSTEM EFFECTS POSSIBLE. (ING 8)

Chemical Properties

HCC:V3
Vapor Density:> AIR
Spec Gravity:0.99
Evaporation Rate & Reference:NIF
Solubility in Water:0
Appearance and Odor:CLEAR WATER-WHITE VISCOUS LIQUID WITH PLEASANT
ODOR.
Percent Volatiles by Volume:60

Stability

Stability Indicator/Materials to Avoid:YES
STRONG BASES, OXIDIZERS, REDUCING AGENTS, ALUMINUM, AND OTHER TYPE
METALS.
Stability Condition to Avoid:WATER CAUSES POLYMERIZATION.
Hazardous Decomposition Products:HYDROGEN CHLORIDE, PHOSGENE, CHLORINE,
CARBON DIOXIDE, AND CARBON MONOXIDE. FLOURIDES .

Disposal

Waste Disposal Methods:MATERIAL MAY BE DISPOSED OF BY A LICENSED
RECLAIMER OR INCINERATION FACILITY. CONSULT LOCAL, STATE AND
FEDERAL DISPOSAL AUTHORITIES FOR APPROVED PROCEDURES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.